Power Quality Analysis
Harmonics & Energy Analysis



 
Harmonics & Energy Analysis

P A 102 DUAL LOAD POWER ANALYZER
     

Providing measurement of all network parameters during each of the network cycles.

 
   


 


 

 

Harmonic Analysis Calculations

Front Panel-Control & Indicators of Power Analyzer

       
 

Front Panel - Control Indicator

Status Indicators
FAULT Indicator Illuminates in one of the following cases:
  - Power Supply malfunction (voltage or frequency)
- Internal malfunction (hardware).
 
REMOTE Indicator lluminates when the PA is controlled by a computer (REMOTE mode
  where all soft keys are disabled).
 
RELAY Indicator Illuminates when the relay is connected.
 
GEN. Indicator Illuminates when energy flows from the load to the network (generally,
  this occurs when generator is being used, and the active power flows in the opposite direction).
 
ELSPEC Logo Indicator Illuminates to indicate mains supply to the Power Analyzer.
 
 
 
Display Controls
7-Segment Display Comprises four 7-segment LEOs.
 
CAP/IND. Indicators Illuminates when the power factor is within the capacitive and
  indicative ranges respectively.
   
Note The CAP. and IND. Indicators are used only for power factor (cosq» and reactive power (Q) measurements.
 
DISP. Softkey Selects the parameter to be displayed
 
Display Parameter The parameter which is selected by the DISP. Softkey is
Indicators marked by the pertinent LED. The LEDs are arranged in two
  rows. Switching between parameters is carried out in a
  cyclic manner by sequentiaaly pressing the DISP. Softkey.
 
HARM.# Softkey Selects the harmonic number (3,5,7, 9, or 11) when measuring H , H or H
 
NORM./MIN./MAX. Selects one of the following display modes
Soft key -NORM. Real-time normal display.
     
  -MIN or MAX Minimum or maximum accumulated value displays are displayed respectively.
   
 
 
 
Mode of Operation Controls
 
INTEGR. Soft key and Pressing this softkey will switch the Power Analyzer into the
Indicator integration mode and the indicator will illuminate. In the integration mode the cosq> value is determined according to the average power factor which is measured during elapsed time (the elapsed time, is defined by the period of time between the programmed time and current time).
 
MODE Softkey Selects one of the following modes of operation
  LOAD 1 Is selected.
  LOAD 2 Is selected.
 
PROGRAM / ELAPSED Illuminates when the PROGRAM mode is selected (the LED
TIME illuminates), or the elapsed time mode is selected. Elapsed Time Mode: Using the arrow softkeys, enables determination of the elapsed time. The elapsed time since the last INTEGR. RESET is shown on the display in three different modes (the arrow softkeys ca.n change same by scrolling) day/hour, hour/min or min/sec. Program Mode: used to set box parameters, such as current transformer ratio, voltage etc. Note: Parameter Settings can be accessed by pressing HARM. + DISP. softkeys simultaneously for at least three seconds.
 
Arrow Softkeys During PROGRAM/ ELAPSED TIME mode, these softkeys are used to
  ncrease or decrease the value of the selected parameter (Program mode) or to select the elapsed time (Elapsed mode).
 
INTEGR. RESET This softkey is used to reset the elapsed time (when MWh is
  selected). This operation is performed by pressing this softkey for at least three seconds.
 
PHASE Softkey This softkey selects the phase to be used as control and
Indiacators measurements reference. When a phase is selected, the pertinent indicator illuminates.
 

   
 